Dialog BOM data
The dialog opens with the command Block BOM, via the row button ✎ in the panel Blocks or BOM data in the Block manager. All values belong to the definition and apply to all instances; at the top right stands n× in the drawing. Context: BOM data per block.

Fields
Block name
The name of the definition as used by panel, Block manager and files. Empty is not applied.
Designation
Text in the column Designation of the parts list; preset with the block name on creation. If it is missing and the article number is missing too, the block counts as no BOM data.
Article number
Key of the parts list: blocks with the same article number form one item (Article number as key). Variants automatically receive the suffix -2.
Standard, Material, Weight, Supplier, Price
Free text fields; they appear as columns in the dialog and the CSV. Standard and material additionally in the inserted table.
Unit
Quantity unit, default Stk.
Remark
Multi-line text, last column in the dialog and the CSV. When a standard part is inserted as block, notes and tags of the part land here.
List as a single part in the BOM
On (default): the block is one item, contained sub-blocks do not count. Off: the assembly is broken down — otherwise the contained blocks are counted (As a single part). Without sub-blocks the check box has no effect.
Buttons
Save applies all fields, increases the block version and reports BOM data saved: Name. Cancel, Esc or a click beside the dialog discard.