Messages about blocks, parts lists and standard parts
Messages appear in the status line at the bottom, as a question of the browser or as red text in the window Block manager. The texts are given as the program shows them; placeholders such as Name or n stand for the respective value.
Creating and placing blocks
First select the elements of the block
The command Create block from selection was run without a selection. Normally the command switches to post-selection first; if the message appears, select elements and call it again.
No valid geometry for the block
The selection contained nothing that can be taken into a block. Select lines, circles, arcs, texts, images or instances.
Block "Name" created — n element(s) · n dimensions · n hatches
Confirmation. The addition with dimensions and hatches appears only if some were taken over. Since v3.0.86 constraints and welds of the elements taken in are removed, as with Del; the addition names them: · n constraint(s), m weld(s) removed, · n constraint(s) removed or · n weld(s) removed. If the message is longer than the status line, hovering over it shows the full text.
Block name:
Label of the floating name field after “Create block”. “Block n” is proposed; Enter or the tick confirm, Esc cancels.
Block "Name": a click places it (multiple times) · R=rotate · H/V=mirror · +/−=scale · ESC/right-click finishes
An instance hangs at the mouse (Inserting instances).
Block placed (n×) — keep clicking or ESC to finish
An instance has been placed; the tool stays active.
Block no longer exists — placement ended
The definition of a running placement was undone (e.g. with Ctrl+Z, which since v3.0.82 also undoes blocks brought along).
Block not found / Target block not found
The definition no longer exists (e.g. after undo). Check the list in the panel. Target block not found is reported by Replace block when the chosen replacement has disappeared in the meantime.
A block cannot contain itself
In the block editor you tried to insert the block currently being edited. Choose another block or save the editor first.
Block editor
Block editor: „Name" — edit the geometry with all tools, then Save or Cancel
The editor is open (Edit block).
Block „Name" saved — n element(s); all instances updated
Confirmation after Save in the editor bar. Since v3.0.80 saving is an undo step in the history of the model: Ctrl+Z undoes the whole edit, Ctrl+Y brings it back. Without a change no step is created.
Block „Name“ saved — To restore: tab “Model”, then Ctrl+Z
The same confirmation when the block editor was opened on a sheet. The step lies in the history of the model; on the sheet an empty step is created. To restore: tab Model, then Ctrl+Z.
Block editing cancelled — no changes applied
Confirmation after Abbrechen (cancel). Since v3.0.81 it is literally true: the drawing is exactly as before the editor — including other blocks changed in the editor, layers with their visibility, BOM fields, guides and drawing information. No undo step is created.
The block editor is already active
Only one editor can be open. Save or cancel the open editor.
Please select a block instance first
Edit block or Block BOM was called without a selected instance. Select an instance, then call again.
Could not open the block editor
Internal error while building the editor. Save the drawing and reload the page.
Block definitions cannot be deleted in the block editor — first click «Speichern» (save) or «Abbrechen» (cancel). · The BOM fields cannot be changed in the block editor — … · The bill of materials is not available in the block editor — … · The drawing cannot be saved while the block editor is open — first click «Speichern» (save) or «Abbrechen» (cancel) in the editor bar. · A standard part cannot be opened for editing in the block editor — …
While the block editor is open, the following are locked: deleting and Clean up in the block manager, the BOM fields of the drawing, the Parts list, saving the drawing (Ctrl+S, Save as), Open a local standard part for editing, as well as tabs, sheets, viewports and Page setup. Remedy: end the editor with Speichern (save) or Abbrechen (cancel) in the editor bar.
Name contains «Block» — a block cannot contain itself · Names contain «Block» — a block cannot contain itself
Since v3.0.78: in the block editor no path (panel, block manager, Ctrl+V, standard part, import drawing, hand-over, Replace with …) can insert a block that is or contains the block being edited. Remedy: use another block.
Cannot save: … The affected insertions are selected — delete them (Del) or click «Abbrechen» (cancel).
Last guard at Speichern (save): the working set contains a chain of blocks, e.g. from an older file. The message also appears as a tab below the editor bar. Such a file opens unchanged; only Del on the selected insertions and saving dissolve the chain.
n× in the drawing — not visible in the block editor; first click «Speichern» (save) or «Abbrechen» (cancel) · n× in another space — choose again there (tab “Model” or a sheet)
Answer of Show in the block manager: the insertions are not in the open space. Since v3.0.74 the block manager counts insertions across the model and all sheets.
Variants and replacing
No block instances selected
Split off as variant or Replace with another block without a selected instance. Select instances.
“Name”: all instances selected — make the change directly in the definition (double-click)
A variant would make no sense because no instance with the old definition would remain. Edit the block directly.
n instances → new variant “Name (2)” — editor opened, the change affects only these
Confirmation; the editor shows the copy.
n new variants created (one per source block)
Instances of several blocks were selected; one variant per block was created, no editor.
No other block available as target
The drawing has only this one definition. Create or load another block first.
Nothing to replace (instances already reference the target block)
The chosen target block is already the definition of all selected instances.
n instances replaced → “Name” / Cannot replace: would create a cycle (block)
Confirmation.
Name now unused (clean up in the block manager)
After replacing, the old definition has no instance any more. It remains; Clean up in the Block manager removes it.
“Name” also occurs in … — replace there as well?
Question when replacing from the Block manager: OK exchanges the block also inside the named assemblies.
“Old” → “New”: n instances · n occurrences in block · replaced · skipped (cycle): block
Confirmation of replacing from the Block manager.
Base point and angle while placing
These messages apply equally when placing blocks, standard parts and copied groups.
Click the new insertion point on the orange preview · B or ESC cancels
Status bar after B while placing. The next click on the orange preview decides at which point the part hangs on the mouse.
Insertion point reset — the preview now hangs at this point / Base point selection cancelled
Status bar after the click, or after B or Esc. The new insertion point applies to this placement only; the block definition stays unchanged.
No snap point on the preview — move closer to a corner/midpoint
Status bar when the click hit no snap point of the preview. Only the preview’s own snap points can be chosen — corners, midpoints, centres. Remedy: move closer to such a point.
Measure angle (auto snap): click the first point · ESC cancels
Status bar after the angle button in the placement field. For the duration of the measurement the tool switches the snap to automatic and restores it afterwards. What is measured is the angle by which the part is placed.
Measure angle: click the second point (direction)
The first point is set; the second gives the direction.
Too close to the first point — click the second point a bit further away
Two almost identical points give no direction. Remedy: click further away.
Angle adopted: a° — preview aligned / Angle measurement cancelled — the previous angle remains
Status bar after the second point or after Esc. The rounded value is shown; the exact one is used for the rotation.
Block manager
Please select a block in the list first.
An action was triggered without a selected row.
No instances placed (block is only contained in other blocks)
Show or Replace with on a block that only occurs as a sub-block.
n instances selected
Confirmation of Show.
Name already taken
When renaming. Choose another name.
Delete block definition Name permanently?
Question before deleting.
The block is still placed n× in the drawing. Delete or explode all instances first. / Block is still in use — delete/explode all instances first
Deleting refused. Delete or explode the instances; the status line reports more briefly Block is still in use — delete/explode all instances first.
The block is contained in Name. Remove it there first. / Block is contained in “Name” — remove it there first
Deleting refused because the block is a sub-block of another definition. Edit the named definition; status line Block is contained in “Name” — remove it there first.
Block definition deleted
Confirmation. On a sheet the deletion is a step in the model; the message then carries the hint To restore: tab “Model”, then Ctrl+Z. Since v3.0.74 the count n× in the drawing covers the model and all sheets.
Delete unused blocks? · n unused blocks deleted
Question and confirmation of Clean up.
No blocks matching „…“ found in this drawing.
The filter matches no block. Show all clears the search field.
No blocks in this drawing
The drawing has no definition yet.
Block "Name" hidden · Block "Name" shown
The eye of a definition was toggled.
Block files
Block "Name" exported: Name.ldblk (incl. n nested)
Confirmation; the file lies in the download folder.
Block export failed: …
Red: the file could not be created or downloaded; the addition names the reason, the cause is in the browser console. No file is created. The Export button in the block manager reports the same.
Not a valid LiberoDraft block file (.ldblk)
The chosen file does not carry the identifier liberodraft-block. Standard part files are wrong here — use Insert local standard part for them.
“Name” not inserted — drawing unchanged (reason)
Red: Load block failed (file unreadable or damaged). Since v3.0.96 the drawing stays exactly as it was. Up to v3.0.95 the message was Block import error: ….
Block "Name" already exists in this drawing. OK = import as a copy · Cancel = cancel the import
Question on a name conflict (Load block), asked by the browser. OK imports the block as a copy, Cancel keeps the existing block.
Block import cancelled — "Name" already existed
You cancelled the question; nothing was changed.
Block "Name" loaded — a click places it (hanging at the mouse), ESC finishes
Confirmation; the main block hangs at the mouse.
Parts list
The drawing contains n hidden block(s). Should they be INCLUDED in the parts list? OK = include · Cancel = leave out
Question when opening the parts list (Hidden blocks). Since v3.0.73 the answer applies per drawing and also to the structured BOM; position balloons never ask (they use the last answer, otherwise they count everything). Insertions on hidden layers count like hidden blocks — for them there are two further versions:
- The drawing contains n insertion(s) on hidden layers. Should they be INCLUDED in the parts list? OK = include · Cancel = leave out
- The drawing contains n hidden block(s) and m insertion(s) on hidden layers. Should they be INCLUDED in the parts list? …
No blocks placed in this drawing
Parts list without block instances in the model; Insert into drawing and Export CSV are greyed out.
(no BOM data)
The block has neither designation nor article number; it counts nevertheless (BOM data).
This structured BOM has no sub-levels and therefore matches the quantity BOM …
Note under the table: every block counts as one part. To break an assembly down into its sub-blocks, clear the check box List as a single part in the BOM in the block's BOM data — the note text names it the same way.
BOM data saved: Name
Confirmation of the dialog BOM data.
Parts list as block “Name” — click to place · Balloons show quantity-BOM item numbers · Balloons show structured item numbers · follows the drawing
The table hangs at the mouse; the additions name the balloon numbering. Since 4.0.1 the inserted table is a live parts list: quantities, parts, values, field selection and language follow the drawing. The most recently inserted one becomes the governing list for the position balloons.
Parts list exported as CSV (n items) · CSV export failed (reason)
Confirmation, or a red error if the file could not be created or downloaded (since v3.0.101 with reason; the cause is in the console). No file is created, the Parts list window stays open.
BOM fields and template
Messages of the BOM fields window and of custom fields (since v3.0.75).
n BOM field(s) taken over from blocks: …
When inserting (standard part, Ctrl+V, load block, DXF …) blocks arrived with fields the drawing did not know yet; they were added to its BOM fields (as text, unless the template knows them).
BOM fields applied · n field(s) added, m adjusted
OK in the BOM fields window, or comparison with the template. The change is an undo step.
Template saved — applies to new drawings · No template saved — new drawings get the standard fields
Save as template for new drawings, or the note in the Bill of materials box of the settings. The template pre-fills new drawings; 🔄 Factory defaults leaves it in place.
Duplicate label: … · Label missing · Value is not a number
Checks on OK: two fields with the same label, a field without label, or in the BOM data form a field of type “number” containing text. Only what is new or changed is checked. Remedy: rename, or enter a number.
The field “…” has values in n block(s). Delete the field together with these values?
Question when deleting a field. OK deletes the field with its values; Ctrl+Z brings both back.
Block “Name” no longer exists — BOM data not saved
The BOM data form was still open when the block disappeared (e.g. with Ctrl+Z). Remedy: reopen the form on an existing block.
Live and governing parts list
Since 4.0.1 an inserted parts list follows the drawing; since 4.0.2 the position balloons follow the governing parts list (right-click Position balloons follow this parts list).
Live parts list — it is built from the drawing and has no BOM data of its own · … cannot be edited in the block editor; cells via «Edit parts list…» (double-click), for a fixed version use «Explode» · … cannot be split off as a variant; for a fixed version use «Explode»
Red: BOM data…, Edit block or Split off as variant on a live parts list (via block manager, Blocks panel or command search; the right-click menu does not offer these entries). The next rebuild would otherwise silently discard a change. Remedy: override cells in the table editor, or Explode for a fixed version.
Position balloons now follow the parts list «Name» · The position balloons already follow the parts list «Name» · To restore: tab “Model”, then Ctrl+Z — balloons follow «Name»
Answer to the right-click Position balloons follow this parts list. The balloons take over the quantity or structured numbering, the answer about hidden parts and the overridden item numbers of this list. On a sheet the step lies in the model (third version). If the governing list is deleted, the most recently chosen one takes over, otherwise the most recently inserted.
The parts list «Name» will be rebuilt from the drawing and will then follow it. Contents changed by hand will be lost (Ctrl+Z undoes this). Replace?
Question for the right-click 🔄 Replace with live parts list on a parts list from a version up to 4.0.0; for several: n parts lists will be rebuilt from the drawing …. The question about hidden parts follows.
Parts list «Name» replaced — follows the drawing · position balloons follow it · n parts lists replaced — they follow the drawing · position balloons follow «Name»
Success: the same definition is now live and governing.
The parts list no longer exists — nothing changed
A menu entry was chosen after the parts list had disappeared (e.g. via Ctrl+Z while the menu was open).
Parts list locked (layer or group) — unlock it first
Double-click or right-click Edit parts list… or Replace with live parts list on a parts list on a locked layer or in a locked group. Remedy: unlock it.
Table editor “Edit parts list”
Messages of the 📋 Edit parts list window (double-click on a live parts list, since 4.0.3/4.0.4). The lines appear in the status line of the window; questions as browser dialogs.
Select a cell and type — the original stays in the block data · Double-click, Enter or F2: edit cell · Del: restore original · Right-click: more commands · Ctrl+Z: undo · Column header: click sorts, drag the edge to change the width, right-click: alignment, show/hide columns
Hint lines of the editor. An overridden cell changes only this parts list, not the block data; it is highlighted in the editor, not in the drawing or print. The part from «Column header» on explains the column headers: sorting, width, alignment, showing and hiding columns (Window, column width and sorting).
Parts list «Name» edited — n cell(s) overridden · … , m value(s) taken over into block data · … · n row(s) hidden · n column(s) hidden · Parts list not changed · To restore: tab “Model”, then Ctrl+Z — parts list «Name» edited
After OK: one undo step (on a sheet in the model, last version). Values marked with ⇢ Take value over into block data are written in the same step. Without a change: Parts list not changed. If rows or columns are hidden, the message appends their number (· n row(s) hidden · n column(s) hidden).
Discard the changes to the parts list?
Esc in the editor after something changed. Cancel discards without asking.
Parts list not opened (reason)
Red: the editor could not be built; the cause is in the console.
Cell cleared · Undone · Redone · Nothing to undo · Nothing to redo · n cell(s) pasted · n cell(s) back to original
Confirmations of editing in the editor: clearing a cell, Ctrl+Z/Ctrl+Y in the editor, pasting from the clipboard, ↺ Whole row back to original or ↺ All cells back to original.
The cell shows the original · The cell shows the original — nothing to take over
Del or ⇢ Take value over into block data on a cell that is not overridden.
«Column» is derived from the drawing · «Column» is calculated from quantity and value
The Qty column and the … total columns cannot be overridden (in a free row they can). The item number (No.) can be overridden since 4.0.4.
Item no. occurs more than once
Tooltip on an item number that occurs more than once in the table; it is marked red with «‼». Equal numbers are allowed («1» and «01» count as equal). After Enter a row moves to its new number; the balloons show the overridden numbers of the governing parts list.
Free row added — no part and no balloon · Free row deleted
+ Free row or ✕ Delete free row. Free rows count in the sum row; they do not appear in the Parts list window or in the CSV.
Overrides deleted · n override(s) assigned to row «Name»
Delete or Assign… for orphaned overrides (their part is no longer in the drawing) below the table. If the part comes back, they apply again.
The same block is already marked with a different value (row «…») · «…» cannot be taken over empty into the block data — the parts list would then show «…» · Only fields of a row with a part can be taken over into the block data · There is no block for this row · Take-over into block data withdrawn
Messages about ⇢ Take value over into block data. The take-over is only marked until OK; Cancel discards it. In the structured BOM the same block can appear in several rows — only one value is allowed. An empty value is refused if the parts list would then show a default.
Change the part number via the block's «BOM data…»
The part number is the key of the row and cannot be overridden in the editor.
n items · n free row(s) · n hidden · n column(s) hidden · ✎ n overridden · ⚠ n original changed since · ‼ n item no. duplicate · ⇢ n into block data · n more not shown
Counters in the header line of the window; all except the number of items appear only when they are not zero. n hidden counts the rows hidden with the eye, n column(s) hidden the hidden columns. n more not shown counts overrides whose row or column the parts list does not show at the moment; its tooltip says: Overrides of rows or columns the parts list does not show at the moment — they are kept and apply again as soon as the row and column appear.
Sorted by «Column» — ascending · Sorted by «Column» — descending · Sorting cleared — by No.
Click on a column header: ascending, descending, then back to the order by No. again. Sorting applies only in the window; the drawn table keeps the order by No. regardless. It is remembered in the browser (Window, column width and sorting).
Alignment «Column»: left / centered / right / automatic
Entries Alignment: … in the menu of a column header (right-click). The alignment belongs to the parts list and, after OK, applies to the drawn table as well; automatic puts numbers right and text left (Column alignment).
View reset
↺ Reset view in the menu of a column header: window position and size, column widths and sorting are back to the defaults. The alignment and hidden columns remain — they belong to the parts list.
Row hidden — missing from the table, the total and the balloons · Row shown · n row(s) shown · No row is hidden
Eye of a row (click or Ctrl + E, tooltip Hide row (Ctrl+E)), or the eye in the column header and Show all rows (tooltip Click: show all hidden rows again). The row stays struck through in the editor; after OK it is missing from the drawn table and the total, and for the governing parts list its position balloon stays empty (Hiding rows).
n item(s) renumbered · The items are already numbered consecutively
🔢 Renumber: the visible parts get consecutive item numbers; hidden and free rows keep their numbers. The balloons follow after OK (Renumbering).
Column «Name» hidden — omitted from the table in the drawing · Column «Name» shown · n column(s) shown · No column is hidden
Hide column in the menu of a column header, or a click in the list Show/hide columns… and Show all columns. After OK the column is missing from the drawn table of this parts list; the Parts list window and the CSV keep showing it. Its overrides are kept (Hiding columns).
«No.» cannot be hidden
Tooltip on the grey entry No. in the list Show/hide columns; Hide column is grey in the menu of this column header as well. The item number stays visible in every parts list.
Parts list copied — n row(s) on the clipboard · Copying to the clipboard is not possible
📋 To clipboard: column headers, visible rows and total row, tab-separated; the count is the number of visible rows. If the browser refuses access to the clipboard, the second message appears — allow clipboard access for this site in the browser settings (Copying to the clipboard).
Item balloon
Item balloon: click an element (ESC ends)
Tool started (Item balloon).
Item balloon n: click its position
The instance was hit, the circle hangs at the mouse; n is the item number.
Note: block is not an item of its own (dissolved assembly?) — balloon shows “?”
The hit block is not an item of the parts list — a dissolved assembly or an excluded block. Click a single part or tick As a single part.
Free balloon: click its position — edit the text via double-click
The click hit an element that is not a block instance. The balloon shows ? until you enter a text.
Free balloon (no reference): click a position — edit the text by double-clicking
The click hit nothing; the balloon has no binding and does not move with geometry changes.
Balloon n placed — click the next block instance (ESC ends)
Confirmation; the tool continues.
Number is live from the BOM — for free text, attach the balloon to a non-block element
Double-click on a balloon on a block instance: the number cannot be changed. For your own text place a free balloon. If there is a live parts list, the balloon takes, since 4.0.2, the number from the governing parts list including overridden item numbers (see Position balloons follow …).
Balloon text
Input field on double-click on a free balloon; empty shows ? again.
Standard parts
No standard parts found (folder normteile/ on the server)
The folder normteile/ is missing or empty, or the program runs without a server. Set up the library on the server or press ⟳.
Standard parts: 3 name(s) were not stored in UTF-8 and were re-encoded for display — please repeat the upload in UTF-8
Cause: File and folder names arrive from the disk as raw bytes. Anyone uploading standard parts from Windows by FTP may have umlauts stored in Windows-1252 instead of UTF-8 on the server, depending on the client. Up to program version v3.0.36 the server then refused any answer and the list stayed empty; since v3.0.37 invalid bytes are replaced, the library appears, and this message names the number of affected names.
Remedy: Upload the affected files and folders again in UTF-8 — set the character set of the FTP client to UTF-8. The re-encoded names are only a stopgap for the display.
Standard part list reloaded
Confirmation of ⟳.
No standard part matches the search
Change the search words; all words must occur.
This folder is empty
The folder contains neither subfolders nor files.
The standard part could not be loaded: …
The file on the server is not reachable or not valid JSON; the addition names the reason.
Invalid standard part file
The file does not carry the identifier liberodraft-part or has no elements. Block files .ldblk belong to Load block.
The standard part contains no valid geometry
No element of the file could be read.
Standard part "Name": a click places it (multiple times possible) · R=rotate · H/V=mirror · +/−=scale · ESC/right-click finishes
The part hangs at the mouse (placement HUD).
Element(s) pasted (n×) — keep clicking or ESC to finish
A part has been placed; the number in brackets counts the clicks so far. The same wording appears when placing from the clipboard, because both use the same path.
Element(s) pasted.
Confirmation after pasting without placing — also without Insert as block. The wording deliberately gives no counts per object type; what the part brings along (dimensions, hatches, welds, constraints) is shown in the group or in the panel Elements.
Placement finished — n standard part(s) inserted
Confirmation after Esc, right-click or Done.
Standard part name: · No storable geometry in the selection
Input field of Save standard part from selection; the second message if the selection contains nothing storable.
Standard part not saved (reason)
Red (since v3.0.101): Save as standard part could not create or download the file; the cause is in the console. No file is created.
Standard part "Name" downloaded — place it on the server in normteile/<category>/
Confirmation; the file lies in the download folder.
Open standard part "Name" for editing? The current drawing will be replaced (Ctrl+Z restores it).
Question of Edit local standard part. Since v3.0.106 the standard part becomes a drawing without a file, named after the standard part: Ctrl+S asks for a location and never overwrites the previous file. A single Ctrl+Z brings the previous drawing back, as the question says.
Standard part "Name" opened for editing — modify, select and use "Save as standard part" again
Confirmation.