Zum Inhalt
LiberoDraft LiberoDraft Help
Deutsch
Start F Messages Messages about blocks, parts lists and standard parts

Messages about blocks, parts lists and standard parts

Messages appear in the status line at the bottom, as a question of the browser or as red text in the window Block manager. The texts are given as the program shows them; placeholders such as Name or n stand for the respective value.

Creating and placing blocks

First select the elements of the block

The command Create block from selection was run without a selection. Normally the command switches to post-selection first; if the message appears, select elements and call it again.

No valid geometry for the block

The selection contained nothing that can be taken into a block. Select lines, circles, arcs, texts, images or instances.

Block "Name" created — n element(s) · n dimensions · n hatches

Confirmation. The addition with dimensions and hatches appears only if some were taken over.

Block name:

Label of the floating name field after “Create block”. “Block n” is proposed; Enter or the tick confirm, Esc cancels.

Block "Name": a click places it (multiple times) · R=rotate · H/V=mirror · +/−=scale · ESC/right-click finishes

An instance hangs at the mouse (Inserting instances).

Block placed (n×) — keep clicking or ESC to finish

An instance has been placed; the tool stays active.

Block not found / Target block not found

The definition no longer exists (e.g. after undo). Check the list in the panel. Target block not found is reported by Replace block when the chosen replacement has disappeared in the meantime.

A block cannot contain itself

In the block editor you tried to insert the block currently being edited. Choose another block or save the editor first.

Block editor

Block editor: „Name" — edit the geometry with all tools, then Save or Cancel

The editor is open (Edit block).

Block „Name" saved — n element(s); all instances updated

Confirmation after Save.

Block editing cancelled — no changes applied

Confirmation after Cancel.

The block editor is already active

Only one editor can be open. Save or cancel the open editor.

Please select a block instance first

Edit block or Block BOM was called without a selected instance. Select an instance, then call again.

Could not open the block editor

Internal error while building the editor. Save the drawing and reload the page.

Variants and replacing

No block instances selected

Split off as variant or Replace with another block without a selected instance. Select instances.

“Name”: all instances selected — make the change directly in the definition (double-click)

A variant would make no sense because no instance with the old definition would remain. Edit the block directly.

n instances → new variant “Name (2)” — editor opened, the change affects only these

Confirmation; the editor shows the copy.

n new variants created (one per source block)

Instances of several blocks were selected; one variant per block was created, no editor.

No other block available as target

The drawing has only this one definition. Create or load another block first.

Nothing to replace (instances already reference the target block)

The chosen target block is already the definition of all selected instances.

n instances replaced → “Name” / Cannot replace: would create a cycle (block)

Confirmation.

Name now unused (clean up in the block manager)

After replacing, the old definition has no instance any more. It remains; Clean up in the Block manager removes it.

“Name” also occurs in — replace there as well?

Question when replacing from the Block manager: OK exchanges the block also inside the named assemblies.

Old” → “New”: n instances · n occurrences in block · replaced · skipped (cycle): block

Confirmation of replacing from the Block manager.

Base point and angle while placing

These messages apply equally when placing blocks, standard parts and copied groups.

Click the new insertion point on the orange preview · B or ESC cancels

Status bar after B while placing. The next click on the orange preview decides at which point the part hangs on the mouse.

Insertion point reset — the preview now hangs at this point / Base point selection cancelled

Status bar after the click, or after B or Esc. The new insertion point applies to this placement only; the block definition stays unchanged.

No snap point on the preview — move closer to a corner/midpoint

Status bar when the click hit no snap point of the preview. Only the preview’s own snap points can be chosen — corners, midpoints, centres. Remedy: move closer to such a point.

Measure angle (auto snap): click the first point · ESC cancels

Status bar after the angle button in the placement field. For the duration of the measurement the tool switches the snap to automatic and restores it afterwards. What is measured is the angle by which the part is placed.

Measure angle: click the second point (direction)

The first point is set; the second gives the direction.

Too close to the first point — click the second point a bit further away

Two almost identical points give no direction. Remedy: click further away.

Angle adopted: a° — preview aligned / Angle measurement cancelled — the previous angle remains

Status bar after the second point or after Esc. The rounded value is shown; the exact one is used for the rotation.

Block manager

Please select a block in the list first.

An action was triggered without a selected row.

No instances placed (block is only contained in other blocks)

Show or Replace with on a block that only occurs as a sub-block.

n instances selected

Confirmation of Show.

Name already taken

When renaming. Choose another name.

Delete block definition Name permanently?

Question before deleting.

The block is still placed n× in the drawing. Delete or explode all instances first. / Block is still in use — delete/explode all instances first

Deleting refused. Delete or explode the instances; the status line reports more briefly Block is still in use — delete/explode all instances first.

The block is contained in Name. Remove it there first. / Block is contained in “Name” — remove it there first

Deleting refused because the block is a sub-block of another definition. Edit the named definition; status line Block is contained in “Name” — remove it there first.

Block definition deleted

Confirmation.

Delete unused blocks? · n unused blocks deleted

Question and confirmation of Clean up.

No blocks matching „…“ found in this drawing.

The filter matches no block. Show all clears the search field.

No blocks in this drawing

The drawing has no definition yet.

Block "Name" hidden · Block "Name" shown

The eye of a definition was toggled.

Block files

Block "Name" exported: Name.ldblk (incl. n nested)

Confirmation; the file lies in the download folder.

Block export failed: … / Export failed

The file could not be written; the addition names the browser's reason. The Export button in the block manager reports the same briefly as Export failed.

Not a valid LiberoDraft block file (.ldblk)

The chosen file does not carry the identifier liberodraft-block. Standard part files are wrong here — use Insert local standard part for them.

Block import error: …

The file is not readable JSON.

Block "Name" existiert in dieser Zeichnung bereits. OK = als Kopie importieren · Abbrechen = Import abbrechen

Question on a name conflict (Load block); this browser question is shown in German. OK imports the block as a copy, Cancel keeps the existing block.

Block import cancelled — "Name" already existed

You cancelled the question; nothing was changed.

Block "Name" loaded — a click places it (hanging at the mouse), ESC finishes

Confirmation; the main block hangs at the mouse.

Parts list

The drawing contains n hidden block(s). Should they be INCLUDED in the parts list? OK = include · Cancel = leave out

Question once per operation (Hidden blocks).

No blocks placed in this drawing

Parts list without block instances in the model; Insert into drawing and Export CSV are greyed out.

(no BOM data)

The block has neither designation nor article number; it counts nevertheless (BOM data).

This structured BOM has no sub-levels and therefore matches the quantity BOM …

Note under the table: every block counts as one part. To break down an assembly, clear the check box List as a single part in the BOM in its BOM data — the note text calls it Break down assembly.

BOM data saved: Name

Confirmation of the dialog BOM data.

Parts list as block “Name” — click to place · Balloons show quantity-BOM item numbers · Balloons show structured item numbers

The table block hangs at the mouse; the addition names the balloon numbering (or … structured item numbers).

Parts list exported as CSV (n items) · CSV export failed

Confirmation or error while writing the file.

Item balloon

Item balloon: click an element (ESC ends)

Tool started (Item balloon).

Item balloon n: click its position

The instance was hit, the circle hangs at the mouse; n is the item number.

Note: block is not an item of its own (dissolved assembly?) — balloon shows “?”

The hit block is not an item of the parts list — a dissolved assembly or an excluded block. Click a single part or tick As a single part.

Free balloon: click its position — edit the text via double-click

The click hit an element that is not a block instance. The balloon shows ? until you enter a text.

Free balloon (no reference): click a position — edit the text by double-clicking

The click hit nothing; the balloon has no binding and does not move with geometry changes.

Balloon n placed — click the next block instance (ESC ends)

Confirmation; the tool continues.

Number is live from the BOM — for free text, attach the balloon to a non-block element

Double-click on a balloon on a block instance: the number cannot be changed. For your own text place a free balloon.

Balloon text

Input field on double-click on a free balloon; empty shows ? again.

Standard parts

No standard parts found (folder normteile/ on the server)

The folder normteile/ is missing or empty, or the program runs without a server. Set up the library on the server or press ⟳.

Standard parts: 3 name(s) were not stored in UTF-8 and were re-encoded for display — please repeat the upload in UTF-8

Cause: File and folder names arrive from the disk as raw bytes. Anyone uploading standard parts from Windows by FTP may have umlauts stored in Windows-1252 instead of UTF-8 on the server, depending on the client. Up to program version v3.0.36 the server then refused any answer and the list stayed empty; since v3.0.37 invalid bytes are replaced, the library appears, and this message names the number of affected names.

Remedy: Upload the affected files and folders again in UTF-8 — set the character set of the FTP client to UTF-8. The re-encoded names are only a stopgap for the display.

Standard part list reloaded

Confirmation of ⟳.

No standard part matches the search

Change the search words; all words must occur.

This folder is empty

The folder contains neither subfolders nor files.

The standard part could not be loaded: …

The file on the server is not reachable or not valid JSON; the addition names the reason.

Invalid standard part file

The file does not carry the identifier liberodraft-part or has no elements. Block files .ldblk belong to Load block.

The standard part contains no valid geometry

No element of the file could be read.

Standard part "Name": a click places it (multiple times possible) · R=rotate · H/V=mirror · +/−=scale · ESC/right-click finishes

The part hangs at the mouse (placement HUD).

Element(s) pasted (n×) — keep clicking or ESC to finish

A part has been placed; the number in brackets counts the clicks so far. The same wording appears when placing from the clipboard, because both use the same path.

Element(s) pasted.

Confirmation after pasting without placing — also without Insert as block. The wording deliberately gives no counts per object type; what the part brings along (dimensions, hatches, welds, constraints) is shown in the group or in the panel Elements.

Placement finished — n standard part(s) inserted

Confirmation after Esc, right-click or Done.

Standard part name: · No storable geometry in the selection

Input field of Save standard part from selection; the second message if the selection contains nothing storable.

Standard part "Name" downloaded — place it on the server in normteile/<category>/

Confirmation; the file lies in the download folder.

Open standard part "Name" for editing? The current drawing will be replaced (Ctrl+Z restores it).

Question of Edit local standard part.

Standard part "Name" opened for editing — modify, select and use "Save as standard part" again

Confirmation.

Related topics