Messages about paper space
Messages appear in the status bar at the bottom, as a tooltip at the pointer or as a browser prompt. The texts are reproduced as the program shows them; placeholders such as n or name stand for the respective value.
Sheets
Layout name:
Prompt after double-clicking a sheet tab. The name entered appears in the tab; an empty name is not accepted.
Delete layout “name” permanently? All sheet elements of this layout will be lost (cannot be undone).
Prompt from “Delete layout” in the “Page setup” dialog. Note: Undo will not help afterwards. Remedy: save first.
Layout deleted
Status bar after the confirmation. If the sheet was open, the program is now in model space.
· n sheet(s) imported
Part of the message when importing a drawing — the sheets of the foreign file were appended.
The area cannot be switched in the block editor — … · The layout cannot be changed in the block editor — … · Layouts cannot be deleted in the block editor — first click «Speichern» (save) or «Abbrechen» (cancel).
Since v3.0.79: while the block editor is open, tabs, +, Delete layout, Page setup, renaming, viewports and 🗒 Insert frame + title block cannot be used; the editor does not reach through a viewport into the model either. On a sheet the editor keeps its own undo history. Remedy: end the editor with Speichern (save) or Abbrechen (cancel).
To restore: tab “Model”, then Ctrl+Z …
Some changes on a sheet affect the drawing as a whole and therefore lie as a step in the history of the model — saving in the block editor, deleting in the block manager, BOM data, the table editor and the governing parts list. Their message then carries this hint at the front; on the sheet an empty step is created. If a message does not fit completely into the status line (on a sheet it is only about 500 px wide at 1920 px), hovering over it shows the full text as a tooltip since v3.0.86.
Creating a viewport
New viewport: click the first corner on the sheet (Escape cancels)
Status bar after “🗔 Draw new viewport”.
Click the opposite corner
Status bar after the first click; the blue frame follows the mouse.
Viewport too small — cancelled
Status bar when width or height is below 5 mm. Remedy: draw it larger.
Cancelled
Status bar after Esc or the right mouse button while drawing.
Viewport created — scale 1:n
Status bar after the second click. The scale is the next standard scale that takes in the whole model.

Working with a viewport
Viewport: click = select (then movable) · drag = selection box · double-click = pan/zoom the model through the viewport · right-click = scale and options
Tooltip at the pointer over an unselected viewport.
Selected viewport: drag = move · corners = size · double-click = pan/zoom the model through the viewport · right-click = scale and options
Tooltip over the selected (blue) viewport.
Active viewport: drag moves the model view, mouse wheel changes the scale — double-click outside finishes
Tooltip over the active (orange) viewport.
Model through the window: drag pans the view, mouse wheel changes the scale — double-click outside to finish
Status bar when a viewport is activated (double-click or “Edit”).
Viewport selected — drag to move, the corner grips resize
Brief hint at the pointer after a viewport has been selected by its frame.
Viewport selected — drag to move it
Status bar after “✥ Move”.
Viewport selected — drag a corner grip to resize
Status bar after “⤡ Resize (corner grips)”.
Viewport is locked — right-click opens its settings
Status bar on a double-click, “Edit”, “Move” or “Resize” at a locked viewport. Remedy: right-click → “🔓 Unlock”.
Viewport locked / Viewport unlocked
Status bar after “🔒 Lock” or “🔓 Unlock”.
Through-hatch selected — not the viewport. Click the frame to select the viewport
Brief hint when a hatch fills the viewport area. Remedy: click the viewport frame.
Scale and view
View fitted — scale 1:n
Status bar after “⤢ Fit to contents”.
Nothing to fit
Status bar with an empty model. Remedy: draw something in model space first.
Viewport scale 1:n: set the model reference scale for line type patterns to 1:n as well? This makes the MODEL show the same patterns as this viewport. The viewport image itself stays unchanged — through the viewport paper sizes apply (true to print).
Prompt after setting a viewport scale when the drawing carries special line types and the scales differ. “OK” adjusts the model’s reference scale so that model and viewport show the same pattern; the viewport image itself stays unchanged. Free zooming with the wheel never asks.
Model reference scale set to 1:n
Status bar after “OK” on the prompt above.
Scale a : b not possible — at most 1 : 1e9 or 1e9 : 1
Since v3.0.105: the typed viewport scale lies outside the limits. Nothing changes, the window stays open. Remedy: enter a scale within the limits.
Outside the viewport — point reset
Status bar when the second point of a through-dimension lies outside the viewport. Remedy: put both points inside the same viewport.
Model value through viewport / Model values through viewport
Note in the “Edit dimension” dialog: the dimension shows the model’s value, not the paper distance (Dimensions in viewports).
Copying and deleting viewports
Viewport copied
Status bar after “⧉ Copy” in the menu or in the “Viewport” dialog.
Viewport deleted
Status bar after “🗑 Delete” in the menu. The through-hatches and through-dimensions of that viewport go with it.
Viewport deleted — Undo restores it
Status bar after “Delete” in the “Viewport” dialog.
The viewport of this through-hatch no longer exists
Status bar when a hatch has lost its viewport. Remedy: undo, or delete the hatch and create it again.
No closed area found in the viewport
Status bar when hatching through a viewport without a closed contour (Hatching in a viewport).
Hatch created in the viewport: pattern
Status bar after a successful through-hatch.
Frame and title block
Frame and title block inserted — n elements (freely editable)
Status bar after “🗒 Insert frame + title block”. Every element can be changed individually.
Active layer is locked/hidden — frame and title block inserted on layer “name”
Status bar when the active layer could not be written to. Remedy: move the elements to the layer you want afterwards (“Properties” panel).